Tag Archives: equipment

How to seal the analyslides

So after the evaporation experiments from the past couple of weeks, I decided to go with the DOW vacuum grease as my sealant. Mostly because it is designed (supposedly) to be resistant to leaks and nonreactive with water, 2 major concerns regarding this project. I’m trusting the manufacturer and the performance of the product in the experiments on this one.

Lid and Slide.

The analyslide has a lid and a base. The base has a circle on it with a slight gap (near the frosted part of the slide), which I’m pretty sure is what helps air escape (creating a decent vacuum) when putting the lid on the base. The top actually has two concentric circles. The inside one is perforated and aligns inside the circle on the base, while the larger circle on the top closes just around the outside of the circle on the base. Since there is no gasket or o-ring in the assembly, the seal isn’t ideal when dealing with water so further measures need to be taken.

Pressing the edges to ensure a tight seal.

After placing the lid on the base, I press the two together. I make sure to keep the analyslide verticle with the frosted side up (unlike what I’m demonstrating to the right). When there is water in the sample the air bubble that remains will align with the hole in the circle on the base of the slide. Doing this prevents water leakage when pressing the lid and base together. I ensure that I press firmly around the entire edge and evenly.

It is also in this step that one must be cautious. When there are seeds in the sample, they tend to float until water has soaked the seed coat. Because of surface interactions that are beyond my understanding at this time, the seeds also move around the surface and tend to migrate towards the edges. When placing the lid on, seeds may end up under the perforated circle or on the top of the base circle. This causes them to be crushed which could cause even more airflow into and out of the sample (because of the added thickness of the seeds).

Innoculating loop that I use to spread my sealant (vacuum grease) over the potential leak spots on the analyslide.

Once the lid is placed on the base, you need to seal the chamber. Previously I used a q-tip because the handle was just the right thickness to fit between the lip on the lid and the base. I eventually switched to a plastic gamma sterilized innoculating loop given to me by a neighboring lab (thanks Nathan!). The loop is a little thinner than the q-tip and I feel allows me better control over sealant application. When sealing, I actually don’t use the loop part at all, and rather use the other end (smearer?) but I’ll still refer to it as the loop for this explanation.

The sealant must be spread evenly over the gap caused by the top-slide interface.

I get a relatively large (but thin) amount on the end of the loop and spread it around the lid-base interface. I make sure to get the majority of the sealant near the gap between the two to ensure a proper seal. Pay extra attention when applying near the sides of the base, because here the lid protrudes a bit and so the sealant must actually be placed near the underside of the slide.

For your viewing pleasure, I am including all the pictures I took (that aren’t too blurry) for this demonstration. I’d like to thank Nadia Fernandez Oropeza for help in taking the images you see here.

Water Evaporation From Analyslide: Setup

I noticed an issue with the water evaporation rate from the sample chambers after the first trial. At first it wasn’t so bad, but got progressively worse. When the second trial came there was a heat wave in the lab (chiller went down for a week), and the evaporation rate increased. I discarded the results anyways because the heat affected the seed growth, but the evaporation rate would have ruined the experiment regardless.

profile of the analyslide, the lid and slide meet on the top side of the slide

Now I’m investigating the best way to seal the chamber while affecting the sample as little as possible. This is important because deuterium/hydrogen exchange could be a major source of experimental error and right now I have no real way of measuring this effect so it may be best to avoid it at all costs. I have purchased/selected sealants based on this. Also, based on the figure to the left, you can see it isn’t very easy to fit many things into that gap created by the top and bottom of the analyslide. The space there is 1/8″ so whatever I use has to either mold to the shape or be small. That is why I chose the following sealants:

sealants

I filled 8 samples with exactly 6mL of DI water. I place the tops of the analyslides carefully on the slide portions and pushed them together slowly so as not to spill any water. I put pressure only on the walls and not the middle of the sample. I then put each sealant around the rim of the analyslide. For the vaseline, Krytox, and DOW Grease I used the giant q-tip seen in the picture to the left to spread the sealant around the area where the lid and the slide meet. For the o-ring and the rubber band I used a clean forceps to move the rubber over the same area. The glue gun glue filled the area between the lip on the top and the slide quite easily. For the parafilm, I cut a small strip (slightly larger than 1/8″ and stretched and wrapped it around the opening. I used to strips in hopes of ensuring a decent seal.

I chose these sealants for various reasons. I was looking for non-reactive “liquids” or suitable solids that could present the least amount of contact/transfer with water. Vaseline, Krytox, and DOW are all nonreactive (maybe not the Vaseline) and hydrophobic. Parafilm is waxy as well but is also a suitable solid. The rubber band and the o-ring were solid enough that I could place them wherever I wanted. The glue gun had the benefit of being a liquid at one point and a solid after cooling.

I was worried that the glue gun would heat the sample considerably but that wasn’t that big a deal. There was some sample heating but it wasn’t very much (although I didn’t measure the exact amount), and the glue cooled quickly.

My guess is the greases and the vaseline will work the best, but they are all the messiest. I don’t think the o-ring will work at all because it never seemed to make contact with the proper edges of the sample. But I have a feeling the rubber band may work well enough.

The experiment results can be seen “live” here.